Install insulation for machinery to reduce the heat generated by the heat teansfer to tha environment from a machine in a factory. A result, the employees in line with increased efficiency. Reduce consumption of heating equipment. Both the light and the heat evenly through the offering plate.

PROPERTY
Can prevent heat from machinery to air. Could heat continuously at a temperature of 200-250 C is used. Installing insulation on and off for easy storage and can also be installed on the mold. machinery, including the still open while cleaning mold manufacture and is not harmful to the organism.

CONCULSION
Insulation to prevent temperature from the fire was about 109 C and the temperature around the machine insulation cover decreased about 7 degree Celsius.
Temperature measurement result comparison between machines with out insulation and insulation.

WITH OUT INSULATOR
T = 163 (Co)
BESIDE MACHINE
T = 59 (Co)
PUT ON INSULATOR



TOP MACHINE
T = 78 (Co)
BEHIND MACHINE
T= 53 (Co)


Temperature measurement results comparison between machine with out insulation and insulation.

EQUIPMENT / TEMPERATURE HEAT CAPACITY TEMPERATURE
AROUND MACHINE
(C) 162  48
COVER INSULATION (C) 53 41
T (C) 109 7